Views: 0 Author: Site Editor Publish Time: 2026-09-21 Origin: Site
Choosing a thermostatic valve for a radiator is not simply a matter of selecting DN15, DN20 or another size. The correct valve depends on how the radiator is connected, where the heating pipe comes from, whether temperature control is manual or automatic, and whether the system requires a thermostatic head or an H valve.
A valve that looks suitable by size may still have the wrong connection or installation direction.
This guide explains the main choices step by step, so you can identify the appropriate thermostatic valve configuration before ordering.
SHUANGLIN VALVE supplies manual and automatic thermostatic valves, angle and straight versions, radiator H valves and thermostatic heads for radiator heating applications.
Before looking at individual products, start with these four questions:
If you need... | Consider... |
Direct manual adjustment | Manual thermostatic valve |
Automatic temperature regulation | Automatic thermostatic valve + thermostatic head |
A valve that changes direction at the radiator connection | Angle thermostatic valve |
A straight pipe arrangement | Straight thermostatic valve |
A PPR pipe connection | PPR Union configuration |
A female threaded radiator connection | PPR Union × Female Thread |
A specific radiator connection arrangement | H valve |
The important point is that these choices can overlap.
For example, a radiator may require an automatic + angle + PPR Union × Male Union configuration. Another installation may require an automatic + straight + PPR Union × Female Thread configuration.
So the valve should be selected as a complete configuration rather than by size alone.
The first decision is whether the radiator needs direct manual adjustment or automatic temperature regulation.
A manual thermostatic valve is adjusted directly by turning the valve control.
It is suitable when the user wants to regulate the radiator manually rather than use a thermostatic head for automatic temperature control.
SHUANGLIN VALVE currently supplies:
Straight manual thermostatic valve: DN15–DN20
Angle manual thermostatic valve: DE20×15, DE25×20, DE32×25
If the application only requires straightforward manual adjustment, there is no need to select an automatic valve and thermostatic head.
An automatic thermostatic radiator valve uses a thermostatic head to sense the surrounding temperature and regulate the water flow through the radiator.
The valve body and thermostatic head therefore work together as a temperature-control assembly.
The current automatic range includes both angle and straight configurations:
PPR Union × Male Union: DE20×15, DE25×20, DE32×25, DE40×32
PPR Union × Female Thread: DN15–DN40, depending on configuration
If automatic temperature regulation is required, the thermostatic head should be considered together with the valve body when specifying the product.
Once you have decided between manual and automatic control, the next question is how the valve needs to sit in the pipework.
The choice between an angle and straight valve is mainly determined by the direction of the pipe and the available installation space around the radiator.
An angle valve changes the direction of the connection between the pipe and radiator.
It can be suitable when the heating pipe approaches the radiator from a direction that requires the valve connection to turn.
Our range includes:
Automatic angle type
PPR Union × Male Union: DE20×15, DE25×20, DE32×25, DE40×32
Male × Female Thread: DN15, DN20
Manual angle type
DE20×15
DE25×20
DE32×25
A straight valve keeps the connection in a straight direction.
It can be considered when the pipe and radiator connection can be arranged along the same line.
Our range includes:
Automatic straight type
PPR Union × Male Union: DE20×15, DE25×20, DE32×25, DE40×32
PPR Union × Female Thread: DN15–DN40
Manual straight type
DN15–DN20
If the installation requires the connection to change direction at the valve, check the angle version.
If the pipe can approach the radiator in a straight line, check the straight version.
The actual radiator and pipe layout should always be checked before ordering.
After selecting the valve type and installation direction, confirm the connection.
This is one of the most important details when ordering thermostatic valves because two valves with the same nominal size may have different connection configurations.
The automatic thermostatic valve range includes:
Available in both angle and straight configurations:
DE20×15
DE25×20
DE32×25
DE40×32
Available in:
Angle: DN15, DN20
Straight: DN15–DN40
These configurations should be specified separately in a quotation.
For example:
Automatic thermostatic valve + straight + Male × Female Thread + DN20
is a more useful specification than simply:
DN20 thermostatic valve
The first description tells the supplier what configuration is actually required.
One detail that can cause confusion when purchasing thermostatic valves is the use of both DN and DE×DN specifications.
Our range includes specifications such as:
DN15, DN20, DN25, DN32, DN40
DE20×15, DE25×20, DE32×25, DE40×32
A DE×DN specification should not simply be shortened to a single DN number when preparing an order.
For example, DE25×20 contains connection information that is not represented by simply writing DN20.
For PPR-connected products, keeping the complete DE×DN specification in the inquiry helps the supplier identify the intended connection.
If you are comparing products from different manufacturers, it is also worth checking how each manufacturer defines its connection notation rather than assuming that every DE×DN designation is interchangeable.
A thermostatic head is the temperature-sensing control component used with an automatic thermostatic radiator valve.
The basic operating principle is:
Temperature changes → thermostatic head senses the temperature → valve adjusts water flow
This is what distinguishes an automatic thermostatic radiator valve from a manually adjusted valve.
If you are ordering an automatic thermostatic valve, the thermostatic head needs to be included or specified as part of the complete configuration.
A manual thermostatic valve does not require a thermostatic head for direct manual adjustment.
Not necessarily.
Different head designs may have different external shapes or appearances without representing a fundamentally different valve body.
When selecting a thermostatic head, the important point is to confirm that it is suitable for the corresponding valve configuration.
An H valve is used for a different radiator connection arrangement from a standard angle or straight thermostatic valve.
It is worth considering when the radiator and heating pipes require an H-type connection.
SHUANGLIN VALVE supplies:
Angle H valve — DN15
Straight H valve — DN15
The choice between angle and straight H valves depends on the actual pipe arrangement.
An H valve should therefore not be selected simply because the radiator is DN15. The connection layout should be checked first.
Looking at actual installation requirements can make the selection process easier.
The radiator requires automatic temperature regulation. The heating pipe uses a PPR connection and approaches the radiator in a way that requires the valve to change direction.
A suitable configuration would be:
Automatic + Angle + PPR Union × Male Union
The required size could then be specified as DE20×15, DE25×20, DE32×25 or DE40×32 according to the pipe and radiator connection.
The radiator requires automatic temperature regulation, the pipe arrangement is straight, and the connection requires a female thread.
A suitable configuration would be:
Automatic + Straight + Male × Female Thread
The available sizes for this configuration are DN15–DN40.
The required thread standard should also be confirmed as BSP or NPT.
The radiator does not require automatic temperature regulation and the user wants to adjust the valve directly.
A manual thermostatic valve can be considered.
The next step is to choose between the available straight or angle configuration according to the pipe layout.
If the radiator installation requires an H-type connection, a standard thermostatic valve may not be the appropriate configuration.
In this case, check the available:
Angle H Valve DN15
or
Straight H Valve DN15
according to the pipe arrangement.
These examples show why specifying only the nominal size is usually not enough.
Before sending an inquiry or purchase order, confirm the following:
Manual
Automatic
Angle
Straight
PPR Union × Male Union
PPR Union × Female Thread
Specify the complete DN or DE×DN designation.
BSP
NPT
Check whether a standard thermostatic valve or an H valve is required.
For automatic valves, confirm the required thermostatic head and its compatibility with the valve body.
Once the installation requirements are clear, the available product configurations can be compared.
Product | Configuration | Available Size |
|---|---|---|
Manual thermostatic valve | Straight | DN15–DN20 |
Manual thermostatic valve | Angle | DE20×15, DE25×20, DE32×25 |
Automatic thermostatic valve | Angle, PPR Union × Male Union | DE20×15, DE25×20, DE32×25, DE40×32 |
Automatic thermostatic valve | Angle, Male × Female Thread | DN15, DN20 |
Automatic thermostatic valve | Straight, PPR Union × Male Union | DE20×15, DE25×20, DE32×25, DE40×32 |
Automatic thermostatic valve | Straight, Male × Female Thread | DN15–DN40 |
H valve | Angle | DN15 |
H valve | Straight | DN15 |
Working pressure: PN16
Working temperature: -10°C to 120°C
Thread options: BSP / NPT
Main application: Radiator heating
The exact connection and size should be confirmed according to the selected configuration.
A clear RFQ should describe the complete configuration rather than only the valve size.
Instead of:
Please quote DN20 thermostatic valves.
A more complete inquiry would be:
Automatic thermostatic valve, straight type, PPR Union × Female Thread, DN20, BSP, with thermostatic head.
For multiple products, each configuration can be listed separately:
Item | Type | Direction | Connection | Size | Thread |
|---|---|---|---|---|---|
1 | Automatic | Straight | PPR Union × Female Thread | DN20 | BSP |
2 | Automatic | Angle | PPR Union × Male Union | DE25×20 | BSP |
3 | Manual | Straight | — | DN15 | BSP |
4 | H valve | Angle | — | DN15 | BSP |
This format reduces unnecessary clarification and makes mixed-product quotations easier to prepare.
Thermostatic valves are primarily used in radiator heating systems and related hydronic heating applications.
Thermostatic valves can be installed at radiator connections to regulate heating water flow.
Different apartments and rooms may have different radiator and pipe layouts, which is why angle, straight and different connection configurations may all be required within the same product range.
In water-based heating systems, heated water circulates through pipes and radiators. A thermostatic valve regulates the water flow entering the radiator according to the control method being used.
For systems where water-flow balancing is also required, a brass balancing valve can serve a different function from the thermostatic valve. The thermostatic valve controls the radiator connection, while a balancing valve is used for system flow balancing.
Radiator heating is also used in some commercial and building heating systems. The appropriate valve configuration depends on the system design and radiator connection.
A thermostatic valve order can usually be specified clearly with seven pieces of information:
Control method → Direction → Connection → Size → Thread → Radiator connection → Thermostatic head
For example:
Automatic → Straight → PPR Union × Female Thread → DN20 → BSP → Standard radiator connection → With thermostatic head
This gives much more useful information than:
DN20 thermostatic valve
If the installation drawing is available, it is also useful to provide it to the valve supplier when the connection is unusual or several configurations are being purchased together.
A thermostatic valve is used in radiator heating systems to regulate the flow of heating water through a radiator.
A manual valve is adjusted directly by the user. An automatic thermostatic valve uses a thermostatic head to sense temperature and regulate the water flow through the radiator.
Check the radiator and pipe layout. An angle valve is used when the connection requires a change in direction, while a straight valve is suitable when the connection can remain in a straight line.
The current automatic range includes PPR Union × Male Union and PPR Union × Female Thread configurations.
The available sizes depend on the configuration and include DN15–DN40 as well as DE20×15, DE25×20, DE32×25 and DE40×32.
A thermostatic head is the temperature-sensing control component used with an automatic thermostatic radiator valve. It senses temperature and controls the valve's water flow.
No. A manual valve is adjusted directly and does not require a thermostatic head for manual operation.
An H valve is a radiator valve designed for a specific radiator connection arrangement. SHUANGLIN VALVE supplies both angle and straight H valves in DN15.
Yes. BSP and NPT thread options are available for the relevant configurations.
The thermostatic valve range is rated at PN16, with a working temperature range of -10°C to 120°C.
The easiest way to choose a thermostatic valve is to work through the installation requirements in order.
First, decide between manual and automatic control. Then check whether the installation requires an angle or straight valve. Confirm the PPR or threaded connection, the exact DN or DE×DN size, and the BSP or NPT thread standard.
Finally, check whether the radiator requires an H valve and whether an automatic configuration needs a compatible thermostatic head.
The important point is that a thermostatic valve should be specified as a complete configuration, not simply by nominal size.
SHUANGLIN VALVE supplies manual and automatic thermostatic valves, angle and straight versions, radiator H valves and thermostatic heads for radiator heating applications.
For a quotation, providing the complete configuration at the beginning makes it easier to identify the correct product and avoid unnecessary back-and-forth during order confirmation.